SAMPLE SYSTEM PROGRAMMING
4-36
d. Enter 1 for Alarm VCR control output. The CCU-100 automatically
enters a 1 for the last Alarm VCR control output because there is
only one Alarm VCR video output programmed.
The screen should appear as follows:
ALARM SETUP
ALARM MONITORS
FIRST - 01 LAST - 01
ALARM VCR VIDEO OUTPUTS
FIRST - 02 LAST - 02
ALARM VCR CNTRL OUTPUTS
FIRST - 01 LAST - 01
e. Press Enter when done to save.
3. Program PreShot 1 on Camera #2 to view the entrance door.
a. Call up Camera 2 on Monitor 1 on the programming JPD-100
Controller.
2 CNT (Control Camera 2)
1 MON CNT (Control Monitor 1)
b. Move the joystick (pan, tilt, zoom) so camera #2 is viewing the
desired location at the front entrance and adjust the focus.