Ultrak CCU-100HD Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sistemas de segurança - controlo de acesso Ultrak CCU-100HD. Ultrak CCU-100HD User`s manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - USER’S MANUAL

CCU-100HDUSER’S MANUALMANUAL NUMBER 518452-1960Ultrak®4465 Coonpath RoadCarroll, OH 43112(800) 443-6680•(740) 756-9222•FAX (740) 756-4237CENTRALCONTR

Página 2 - Issue 1 – November 1998

TERM DEFINITIONSector ID Sector IDs are used for labeling specific areas that the SmartScanunit views. Up to 16 Sector IDs can be programmed and stor

Página 3

SETTING UP ALARM MONITORS/VCRS4-324.4 SETTING UP ALARM MONITORS AND VCRs.The CCU can be programmed to designate monitors as alarm monitors (AM) andVCR

Página 4

SETTING UP ALARM MONITORS/VCRs4-33OUTPUTS as ALARM VCR VIDEO OUTPUTS. The control outputs areused to turn the VCRs on and off.2. Enter the first vide

Página 5 - IMPORTANT SAFEGUARDS

SAMPLE SYSTEM PROGRAMMING4-344.5 SAMPLE SYSTEM PROGRAMMINGThe following examples provide some typical situations and the methods usedfor programming t

Página 6

SAMPLE SYSTEM PROGRAMMING4-351. Outline your system.SmartScan Unit (Ceiling Entrance) = Camera #2.Monitor in Office = Video Output (Monitor) #1Alarm (

Página 7 - SAFETY PRECAUTIONS

SAMPLE SYSTEM PROGRAMMING4-36d. Enter 1 for Alarm VCR control output. The CCU-100 automaticallyenters a 1 for the last Alarm VCR control output becau

Página 8 - SENSITIVE

SAMPLE SYSTEM PROGRAMMING4-37c. Press Shift F5 on the KBD-100A keyboard.d. Type 1 for the PreShot Number and press Enter.e. Type the title of the PreS

Página 9

SAMPLE SYSTEM PROGRAMMING4-38FUN NUM CAM MISC DWELL00 C AM 2 0001 C AR 2 0002 P 1 2 0.0 1003 C AA 0004ENTER FUNCTIONP,V,M,C,AMultiCall Line Definition

Página 10

SAMPLE SYSTEM PROGRAMMING4-39b. Press Ac. Type 4 and press Enter.d. Next to the 4 in the MC column, type 1e. Press Enter.f. Press Esc to exit programm

Página 11

SAMPLE SYSTEM PROGRAMMING4-40Perform the following steps to program the system to respond as requiredabove.1. Outline your system.Receiving Dock Camer

Página 12

SAMPLE SYSTEM PROGRAMMING4-41g. Press Esc to exit programming PreShots.3. Program MultiCall 7 for alarm 5. Send camera 6 to PreShot 4, callcamera 6 t

Página 13

iTABLE OF CONTENTSPageSECTION 1. INTRODUCTION ...1-11.1 DESCRIPTION.

Página 14

SAMPLE SYSTEM PROGRAMMING4-4202 = Turn on Auxiliary Contact Output 103 = Send Camera Six to PreShot 4, then wait 15 seconds.04 = Turn off Auxiliary Co

Página 15

4-43Table 4-2. KBD-100A KEYBOARD COMMANDSCommand DefinitionF1 "GO TO" PreShotF2 Run VectorScan OnceF3 Run VectorScan ContinuouslyF4 Run Mul

Página 17

5-1SECTION 5. MAINTENANCE5.1 GENERALThis section contains the information on preventive maintenance andtroubleshooting at a user's level for the

Página 18

5-2If problems still exist after verifying correct installation and the problemhas been isolated to the Central Control Unit, then it must be removed

Página 19

A-1APPENDIX A. SYSTEM CONFIGURATIONA.1 GENERALPrior to programming the CCU-100, identify all pieces of equipment and theiraddresses in your specific

Página 20

A-2Table A-1. AIU-100 ADDRESSINGON = 0OFF = 1AIU # Switch PositionAddress 1 2 300001100201031104001510160117111A.1.2.1 AIU-100 Cross Reference for Al

Página 21

A-3A.1.3 SHB-100 ShotboxThere are sixteen possible SHB-100 addresses (0-15). The SHB-100 addressesare set using a 4-position DIP switch, S17.The foll

Página 22

A-4A.1.4 Camera NumbersThe HD video switcher supports 128 cameras. The camera address and the videoinput number should be the same. The camera addres

Página 23 - ENVIRONMENTAL

A-5SYSTEM COMPONENTSJPD-100 ADDRESSESAddress Location Address LocationAddress Location Address LocationAIU-100 ADDRESSESAddress Alarm #’s Address Alar

Página 24

iiTABLE OF CONTENTS (CONT)Page3.2 OPERATING PROCEDURE ...3-13.2.1 JPD-100 Contr

Página 25

A-6MONITOR ADDRESSES (Video Output On Switcher)Address Location Address LocationVCR ADDRESSES (Video output on Switcher)Address Location Address Locat

Página 26

A-7A.2 PROGRAMMING RECOMMENDATIONSThe following steps are recommended to organize the programming efforts of theSmartScan System.1. Identify and progr

Página 27

A-8A.3 PROGRAMMING WORKSHEETSThe following worksheets are included to organize the programming efforts for theCCU-100.Sector Programming LogPreShot Pr

Página 28

A-9SECTOR PROGRAMMING LOGPage 1 of 2This form is used to program Sector ID’s. A review of the area or the drawings coveringthese areas should be done

Página 29

A-10SECTOR PROGRAMMING LOG (cont)Page 2 of 2CAMERA NUMBER ______SECTOR NAME COVERAGE6789101112131415

Página 30

A-11PRESHOT PROGRAMMING LOGPage 1 of ___This form is used to program PreShots in the SmartScan units. One form or series of formscan be used for eac

Página 31

A-12PRESHOT PROGRAMMING LOGPage ___ of ___CAMERA NUMBER _____PreShot # Name Coverage

Página 32

A-13VECTORSCAN PROGRAMMING LOGPage ___ of ___This form is for programming VectorScans in SmartScan units. A form or series of formscan be used for ea

Página 33

A-14VECTORSCAN PROGRAMMING LOGPage ___ of ___CAMERA NUMBER _____VECTORSCAN NUMBER ________DESCRIPTION ________________________________________________

Página 34

A-15AIU-100 ALARM LOGPage ___ of ___This form is for assigning MultiCalls to alarm inputs and describing the system functions inthe MultiCall. There

Página 35

iiiTABLE OF CONTENTS (CONT)Page4.3.7.1 JPD-100 Function Key or SHB-100 Function Key...4-204.3.8 Assigning MultiCalls to Alar

Página 36

A-16AIU-100 ALARM LOGPage ___ of ___AIU # ___Alarm # MultiCall # Description of MultiCall

Página 37

A-17MULTICALL LOGPage ___ of ___There can be up to 256 MultiCalls (0-255). MultiCalls can be assigned to AIU-100/AIF-100/IN Alarm Inputs, JPD-100 Qui

Página 38

A-18MULTICALL LOGPage ___ of ___MultiCall # Assigned To Description

Página 39 - CLOSEOPEN

A-19MULTICALL WORKSHEETMultiCall # _____Description Assigned to (May have more than one assignment)The following table shows the required data and the

Página 40

A-20MULTICALL _______FUN NUM CAM MISC DWELL00010203040506070809101112131415161718192021222324252627282930

Página 41

B-1APPENDIX B. PROGRAMMING AIF-100 ALARM INPUTSB.1 GENERALThis appendix provides the programming information for the AIF-100/IN AlarmInput Auxiliary

Página 42

B-2To program the alarm inputs, a MultiCall must be programmed and stored in theCCU-100 Central Control Unit; then assigned to the alarm input. To de

Página 43

B-3The following display appears on the screen.PROGRAM RESPONSE TO:C > Camera/Monitor SetupA > AlarmsJ > JPD-100 JPD Quick SwQ > SHB-100 S

Página 44

B-4For example, enter alarm number 25.The following display appears.NUM--MC NUM--MC NUM--MC25-- ··· 26-- ··· 27-- ···28-- ··· 29-- ··· 30-- ···31-- ··

Página 45

B-5To delete MultiCalls from alarms, press the space bar until the MultiCallnumber is erased.5. Press ENTER when done assigning MultiCalls to alarms.T

Página 46

ivTABLE OF CONTENTS (CONT)PageAPPENDIX B. PROGRAMMING AIF-100 ALARM INPUTS ... B-1B.1 GENERAL ...

Página 47

B-6The AIF-100/CI provides the interface between the CCU-100 and the alarminputs in each of the AIF-100/AL and AIF-100/IO units connected to it. An A

Página 48

B-7The alarm inputs on AIF-100/AL address 1 are AIU 0, 9 through 16. These willappear on the JPD-100 display as alarm 9 through 16.The alarm inputs o

Página 49

B-82. Alarm inputs 1 through 8 on AIF-100/AL addressed as 1 are AIU 0,alarm inputs 9 through 16. These alarms will appear on the JPD-100display as al

Página 50

B-9B.3.1 Assigning MultiCalls to AIF-100/AL and AIF-100/IO Alarm InputsPerform the following steps to program the alarm inputs.1. Press Shift F10 on t

Página 51

B-10The alarm number entered is the first number appearing in the upperleft corner of the screen. Thirty alarm numbers appear on the screen ata time.

Página 52

B-112) Press the gray page down key to move to the top of the next pageof alarms.3) Use the gray arrow keys to move to the next page or the previouspa

Página 54

C-1APPENDIX C. MODEL CCU-100/HD QUICK REFERENCE GUIDECCU -100/HD OR CCU-100/HD/X CENTRAL CONTROL UNITWITH JPD-100 CONTROLLER AND KBD-100A KEYBOARDAll

Página 55

C-2FUNCTION DEFINITION PROCEDUREProgram MultiCall(Continued)P = PreShotFUN NUM CAM MISC DWELLP 0-99 1-128 0-9.9 00-99V = VectorScanFUN NUM CAM MISC DW

Página 56

C-3FUNCTION DEFINITION PROCEDUREProgram MultiCall(Continued)A = Auxiliary Output ControlFUN NUM CAM MISC DWELLA AUX# 1-250* 1 (ON) 00-990 (OFF)*Addres

Página 57

vLIST OF TABLESTable 4-1. KEYBOARD PROGRAMMING NOTES ...4-2Table 4-2. KEYBOARD COMMANDS ...

Página 58

C-4FUNCTION DEFINITION PROCEDUREStop MultiCall JPD-100 ControllerJPD-100 Function KeySHB-100 Function KeyStop All MultiCallsMCALL>3If started from

Página 59

C-5FUNCTION DEFINITION PROCEDUREProgramming AlarmInputsUp to 255 alarms can beprogrammed1. Program a MultiCall for thealarm input. See Call-UpVideo

Página 60

C-6FUNCTION DEFINITION PROCEDURECall-Up Video FromAlarm Inputs OnAlarm VCRProgram MultiCall to call-upvideo from alarm inputs toalarm VCR (placingfoll

Página 61

C-7FUNCTION DEFINITION PROCEDUREProgrammingSHB-100 FunctionKeysUp to sixteen SHB-100s (0-15).1. Program MultiCall for eachkey.2. Assign MultiCall to F

Página 62

C-8FUNCTION DEFINITION PROCEDUREMonitor Setup Position Date/Time Displayand Camera Title DisplayEnable or disable thetime/date displayEnable or disabl

Página 64 - Activate an Alarm

1-1SECTION 1. INTRODUCTION1.1 DESCRIPTIONThis manual provides the installation, operation, programming, and maintenanceprocedures for the CCU-100/HD

Página 65 - Reset an Alarm

1-2• SmartScan Programming PreShots, VectorScans, and Sector IDs stored in SmartScan assemblies areprogrammed using the CCU-100 Central Control Unit,

Página 66

1-3 Up to eight AIU-100 units can be connected to the CCU-100 for 255 alarminputs. Up to eight AIF-100/IN units can be connected to the CCU-100 for 6

Página 67

Issue 1 – November 1998Issue 1, Revision A – March 1999 – added host computer interface on COM 1, added operation andprogramming for video alarms and

Página 68

1-4• Ultrak HD Series Video Switcher Interface The CCU-100/HD Central Control Unit communicates with an Ultrak HD SeriesSwitcher at COM2. The CCU s

Página 69

1-5 When a video alarm occurs, the CCU starts the MultiCall assigned to the videoalarm type. The default MultiCall for all video alarm types is 000.

Página 70

1-6Baud Rate: 1200, 2400, 9600, or 19.2K Baud Selectable byDIP Switch for Each Rear Panel CommunicationsPortCPU Communications: RS-232 or RS-485Full D

Página 71

1-7ENVIRONMENTALTemperature Limits: 32°F to 122°F (0°C to 50°C)Humidity Limits: 0% to 95%, non-condensing

Página 73

2-1SECTION 2. INSTALLATION AND INTERCONNECTIONS2.1 GENERALThis section describes the cabling requirements, DIP switch and jumper settings,the connect

Página 74

2-22.2.1.1 DIP Switches (S1-S4) for Communication SettingsThe circuit board inside the CCU chassis has four DIP Switches, S1through S4, for setting th

Página 75

2-3Channels 1, 3, 5, and 7Baud Rate Sn-4 Sn-51200 ON ON2400 OFF ON9600 ON OFF19.2K OFF OFFn = 1 for channel 1, n = 2 for channel 3, n = 3 for channel

Página 76

2-4DIP switches S1 - S3 are be set for 9600 baud, even parity as follows:DIP Switch S1 – S3Switch Position ON/OFF1ON2OFF3ON4ON5OFF6ON7ON8ONDIP switch

Página 77

2-52.2.2 JumpersThere are several jumpers on the circuit board inside the CCU chassis. Thechassis cover has to be removed to set the jumpers. These

Página 78

WARNINGTHIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT,THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICHCASE THE USER MAY BE REQUIRED TO TAKE A

Página 79

2-62.2.2.3 Watchdog TimerJumper W42 on the printed circuit board enables or disables the systemwatchdog timer. Jumper W42 is IN.2.2.2.4 Interrupt Jum

Página 80

Figure 2-1. MODEL CCU-100/HD or CCU-100/HD/X EQUIPMENT BLOCK DIAGRAM

Página 81

2-82.3.1 Model CCU-100/HD Front Panel.The CCU front panel has a connector for a JPD-100 Joystick Controller anda KBD-100A Programming Keyboard. The J

Página 82

2-92.3.1.1 Front Panel Cabling Requirements• ControllerUse only the coiled cable supplied with the JPD-100 JoystickController for connection from the

Página 83

2-10CONTROLLERPin 3 RX-Pin 4 5 VoltPin 5 GNDPin 6 TX-KEYBOARDPin 1 ClockPin 2 DataPin 3 ResetPin 4 GroundPin 5 5 Volt2.3.2 Model CCU-100/HD Rear Panel

Página 84

2-11REAR PANEL EQUIPMENT CONNECTIONSChannel 6 RS-485 Control Data Output(FastScan, SmartScan, or CRX500Series or CRX800 Series ControlReceivers, AIF-1

Página 85

2-122.3.2.2 Rear Panel Connector Pin-Out Assignmentsa. Channels One through Eight - Channels one through eight on therear panel are 6-pin DIN connecto

Página 86

2-13TerminationChannel Resistor Jumper3R15W364R16W375R17W386R18W397R19W408R20W41b. COM 1 and COM 2COM 1 and COM 2 are RS-232 ports. COM 1 is for conn

Página 87

2-14COM 2 PIN ASSIGNMENTSPin 2 TX Output dataPin 3 RX Input dataPin 7 GND2.3.2.3 Equipment Interconnections.The following paragraphs and illustrations

Página 88

Figure 2-3. EQUIPMENT CONNECTIONS FOR CHANNELS 1, 2, AND 3NEARCLOSEOPENFAR

Página 89

DECLARATION OF CONFORMITYTo The European Community Council Directive 89/336/EECISSUED BY: Ultrak®, Inc.4465 Coonpath Road NWCarroll, OH 43112USATel:

Página 90

2-16• Channels 4 and 6Channels 4 and 6 are used to output the control data for theFastScan assemblies, SmartScan assemblies, and CRX500 Seriesor CRX8

Página 91

Figure 2-4. EQUIPMENT CONNECTIONS FOR CHANNELS 4 AND 6

Página 92

2-18• Channel 5Channel five is the interconnect for the AIU-100 Alarm InterfaceUnits and SHB-100 Shotboxes. Up to 16 units (either AIU-100s orSHB-100

Página 93 - 05 12/26-19:00 03-04:00

Figure 2-5-1. EQUIPMENT CONNECTIONS FOR CHANNEL 5

Página 94

Figure 2-5-2. EQUIPMENT CONNECTIONS FOR CHANNEL 5

Página 95

Figure 2-5-3. EQUIPMENT CONNECTIONS FOR CHANNEL 5

Página 96

2-22• Channels 7 and 8Channels 7 and 8 are not used.• COM 1COM 1 is for connection to a Host Computer (by others).CCU-100/HDCOM 1 TOHOSTCOMPUTERPin 2

Página 97

2-23/2-24CCU-100HDCOM Port 2Ultrak HD SeriesSwitcherRJ-11 ConnectorPin 2, TX Pin 3, RXPin 7, GND Pin 4, GNDPin 3, RX Pin 5, TX2.4 INSTALLATION DRAWING

Página 100

IMPORTANT SAFEGUARDS1. Read Instructions - All the safety and operating instructions should be read before the unit isoperated.2. Retain Instructions

Página 102

3-1SECTION 3. OPERATION3.1 CONTROLS AND INDICATORSThe only control on the CCU is the power input selection on the rear panel. Thepower input is sele

Página 103

3-2address 1 is sent out COM 2 to the video switcher. Auxiliary control data forall other addresses is sent out channels 4 and 6.a. JPD-100 Function

Página 104

3-3the CCU updates all other controllers with the same monitorselected to reflect the camera change.For example:JPD-100 Controller #1 has camera #1 an

Página 105

3-4If an operator calls a control camera displayed on one of theother JPD-100s in the system; the operator gets control of thecamera. The other contr

Página 106

3-53.2.2 RS-485 Control Output InterfaceThe Model CCU -100 Central Control Unit sends all control data forFastScan or SmartScan assemblies and CRX-500

Página 107

3-6for programming auxiliary control commands in MultiCalls. Refer to the JPD-100 Joystick Controller User’s Manual for manually switching video. The

Página 108

3-7display monitor and starts the MultiCall assigned for the video alarm type.The alarm message is displayed two lines above the selected position for

Página 109

3-83.2.3.1 MX-4248 I/O Module OptionThe MX-4248 I/O module has 24 alarm inputs and 8 contact outputs. Ifthe MX-4248 I/O Module is installed, the alar

Página 110

3-9If a MultiCall is assigned to a specific date and time, the CCU starts theMultiCall when its internal clock reaches the programmed date and time.

Página 111

13. Power Lines - An outdoor system should not be located in the vicinity of overhead power lines orother electric light or power circuits, or where i

Página 112

3-10NOTEIf an alarm occurs that is disabled by anoperator at the JPD-100 Controller, the CCUdoes not respond. If an alarm occurs that isnot assigned

Página 113

3-11While an alarm monitor is being used to display alarms, an operator cannotmanually switch another camera to the monitor.EXAMPLE:The alarm monitors

Página 114

3-12While an alarm VCR is being used to record alarms, an operator cannotmanually switch another camera to the VCR or turn the VCR off.EXAMPLE:The ala

Página 115

3-13Acknowledging AlarmsAlarms can be automatically acknowledged in the MultiCall or manuallyacknowledged on the JPD-100 Controllers. Alarms can be a

Página 116

3-143.2.7 AIF-100/CO Contact Output Control InterfaceThe CCU sends all contact output control data for AIF-100/CO auxiliarycontrol devices (address 2-

Página 117

3-15• Reset an AlarmWhen the CCU receives a reset alarm command, the CCU acknowledgesthe alarm and stops the MultiCall assigned to the alarm. A rese

Página 118

3-16Send a SmartScan to a PreShotBitByte76543210Byte00 10100000ASCII “P” (5016)1PreShot Number (0-99)12Camera Number (1-250)23Checksum3Byte76543210Byt

Página 119 - SYSTEM COMPONENTS

3-17Reset an AlarmBitByte76543210Byte00 10100100ASCII “R” (5216)1Alarm Number (1-255)12Checksum2Byte76543210ByteBitRun a MultiCallBitByte76543210Byte0

Página 121

4-1SECTION 4. PROGRAMMING4.1 ON-SCREEN HELPThe F12 function key on the KBD-100A keyboard provides an on-screen helpmenu. The menu has a brief descri

Página 122

SAFETY PRECAUTIONSCAUTIONRISK OF ELECTRICSHOCK, DO NOT OPENCAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPENCOVERS. NO USER SERVICEABLE P

Página 123

ON-SCREEN HELP AND PROGRAMMING NOTES4-2Shifted Key FunctionSF1 Program SmartScan OptionsSF5 Program PreShotPressing the F12 function key a fourth time

Página 124

PROGRAMMING THE CCU-100/HD4-34.3 PROGRAMMING THE CCU-100/HD CENTRAL CONTROL UNITA JPD-100 Joystick Controller, a KBD-100A Keyboard, and a Diamond Seri

Página 125

PROGRAMMING THE CCU-100/HD4-4Restoring Factory Default SettingsThis same jumper, W44 can be used to restore the CCUs default settings asshipped from t

Página 126 - PreShot # Name Coverage

DEFINING MULTICALLS4-54.3.1 Defining MultiCallsMultiCalls are used to define the CCU’s response to events such as dateand time, alarms, JPD-100 Contro

Página 127

PROGRAMMING MULTICALLS4-64.3.2 List Programmed MultiCallsPerform the following steps to list the programmed MultiCalls.1. Press F11.Each time function

Página 128

PROGRAMMING MULTICALLS4-7The letters of the functions that are programmable are listed at thebottom of the screen.Function Descriptions:P - PreShotV -

Página 129

PROGRAMMING MULTICALLS4-85. When done entering functions, press ENTER .6. Press S to Save the MultiCall or D to Delete the MultiCall entirely. If you

Página 130 - Page ___ of ___

PROGRAMMING MULTICALLS4-94.3.3.1 P - PreShotTo program the MultiCall to perform a PreShot, perform the followingsteps.NOTEIf the cursor does not autom

Página 131

PROGRAMMING MULTICALLS4-104.3.3.2 V - VectorScanTo program the MultiCall to perform a VectorScan, perform the followingsteps.NOTEIf the cursor does no

Página 132 - MULTICALL LOG

PROGRAMMING MULTICALLS4-114.3.3.3 M - MultiCallTo program the MultiCall to perform a MultiCall (including itself), performthe following steps.NOTEIf t

Página 133

HANDLING ELECTROSTATIC-SENSITIVE DEVICESATTENTIONOBSERVE PRECAUTIONSFOR HANDLINGELECTROSTATICSENSITIVEDEVICESWARNINGELECTROSTATIC SENSITIVE DEVICE. U

Página 134

PROGRAMMING MULTICALLS4-124.3.3.4 C - CallThe Call function provides four system actions.1. Call a camera to a monitor2. Call a camera to an alarm mon

Página 135

PROGRAMMING MULTICALLS4-131. Enter C in the FUN field.2. Enter the monitor number (1-32) in the NUM field.3. Enter the camera number (1-128) in the CA

Página 136

PROGRAMMING MULTICALLS4-14C - Call (Alarm Monitor or Alarm VCR)The AM and AR functions must be the first steps in the MultiCall. Thefirst step, if bo

Página 137

PROGRAMMING MULTICALLS4-15monitor or record the alarm site before acknowledging the alarm.The alarm acknowledge function can occur anywhere in theMult

Página 138

PROGRAMMING MULTICALLS4-164.3.3.5 A - Auxiliary Output Control (such as VCRs)The auxiliary output control function is used to energize or de-energizer

Página 139

PROGRAMMING MULTICALLS4-174. Enter 1=On or 0=Off in the MISC field.1 turns the contact on: if a normally open contact, on closes thecontact; if a nor

Página 140

EDITING/DELETING MULTICALLS4-184.3.4 Editing an Existing MultiCallTo Edit a MultiCall, perform the same steps as programming a MultiCall.Use the gray

Página 141

START/STOP MULTICALLS4-194.3.6 Run MultiCallA. KBD-100A KeyboardTo run a MultiCall from the KBD-100A keyboard, perform the followingsteps.1. Press fun

Página 142

ASSIGNING MULTICALLS4-204.3.7.1 JPD-100 Function Key or SHB-100 Function KeyTo stop a MultiCall started from a JPD-100 Function Key or SHB-100Function

Página 143

ASSIGNING MULTICALLS4-21Perform the following steps to assign MultiCalls to alarms.1. Press Shift F10.2. Press A for Alarm Inputs.3. Enter the alarm n

Página 144

DEFINITIONS OF TERMSThe following terms are used often in this manual. Please become familiar withthem before programming and operating the CCU-100/H

Página 145

ASSIGNING MULTICALLS4-22To delete MultiCalls from alarms, press the space bar until theMultiCall number is erased.6. Press ENTER when done assigning M

Página 146

ASSIGNING MULTICALLS4-234.3.10 Assigning MultiCalls to JPD-100 Function KeysThe CCU can be programmed to assign MultiCalls to JPD-100 FunctionKeys. W

Página 147

ASSIGNING MULTICALLS4-244.3.11 Assigning MultiCalls to Date and TimeA MultiCall can be assigned to Date and Time. When the clock in the CCUreaches th

Página 148

ASSIGNING MULTICALLS4-25After the MultiCall is run on 12/23 at 3:00 PM, the CCU updates the starttime to reflect the next time the MultiCall is run.St

Página 149 - A AUX# 1-250* 1 (ON) 00-99

SETTING DATE AND TIME4-264.3.12 Setting the Date and Time in the CCU-100/HD Central Control UnitTo set the date and time on the clock in the CCU, perf

Página 150

CAMERA AND MONITOR SETUP4-274.3.13 Camera and Monitor SetupThe Ultrak HD Video Switcher can be programmed using the CCU-100/HDor CCU-100/HD/X Central

Página 151

CAMERA AND MONITOR SETUP4-28The default factory settings are as follows:1) Default camera titles (CAM xxx) and date and time displays are enabledfor a

Página 152

CAMERA AND MONITOR SETUP4-29inputs that do not have video connected to them. False loss of syncalarms will be generated on video inputs with no video

Página 153

CAMERA AND MONITOR SETUP4-30g. Press 7 to assign a MultiCall to a loss of sync alarm.Enter the MultiCall number (000-255) and press Enter. Thedefault

Página 154

ALARM CONFIGURATIONOPTIONAL MX-4248 I/O MODULE4-314.3.14 HD Switcher MX-4248 Optional I/O ModuleThe optional MX-4248 I/O Module has 24 alarm inputs.

Comentários a estes Manuais

Sem comentários